Skip to content

Quality Assurance & Dosimetry

QUASAR Winston-Lutz Wand Phantom

The QUASAR® Winston-Lutz Wand identifies a LINAC's true isocenter with submillimeter accuracy using the XYZ micrometer assembly. It is used with MV/KV Beam and portal imagers for precise radiation isocenter alignment.

QUASAR Winston-Lutz Wand Phantom

The QUASAR® Winston-Lutz Wand identifies a LINAC's true isocenter with submillimeter accuracy using the XYZ micrometer assembly. It is used with MV/KV Beam and portal imagers for precise radiation isocenter alignment.

Compatible with: CT Simulation, Bore-type linacs, IGRT, Machine Targeting, TG142

Used for: Imaging QA RT, Monthly QA RT

Features

Accuracy and Precision

The primary advantage that the QUASAR™ Winston-Lutz Wand has over similar products is that all three axes can be accurately adjusted using the built-in micrometers. This allows the user to place the phantom precisely at the radiological isocenter for accurate adjustments.

Alignment Confidence

Achieve submillimeter agreement between the true radiological isocenter and room lasers. While similar options are included with some SRS/SBRT packages, the QUASAR™ Winston-Lutz Wand is an economical alternative for those wishing to achieve high accuracy without the expense of purchasing an SRS package.

Intuitive Design

7/16” (11.1125 mm) Steel BB embedded in acrylic wand, providing sub-millimeter accuracy. XYZ Micro Stage enables simple adjustment for positioning the wand in three dimensions, and a counterbalanced stand provides ease of use and placement on the treatment couch.

Compatibility

Verify MV and KV imaging alignment with an intuitive process to ensure true isocentre and room laser coincidence. Compatible with LINACs and EPIDs from multiple vendors with easy attachment to the treatment couch.

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT

Talk to our team

Questions about a system, a quotation or after-sales support? Call or email us and the right person will get back to you.