QUASAR MRID³ᴰ

An industry-leading distortion analysis phantom that is trusted globally by medical physicists for third party MR-SIM and MR-LINAC commissioning and quality assurance.

QUASAR MRID³ᴰ

An industry-leading distortion analysis phantom that is trusted globally by medical physicists for third party MR-SIM and MR-LINAC commissioning and quality assurance. Its large FOV design allows for quick setup and scanning in less than 10 minutes, with a built-in software for detailed image analysis.

Compatible with: Adaptive, Bore-type linacs, MR Simulation, MR Guided Radiotherapy, Helical linac, Small Field Dosimetry, SGRT, TG284

Used for: Imaging QA RT, Commissioning and Annual QA RT

Learn how QUASAR® MRID 3D phantom eases the introduction of MRI into your radiotherapy department.

The QUASAR MRID 3D geometric distortion analysis system from IBA Dosimetry enables physicists to exploit the power of the MR-only radiotherapy workflow!

Features

Workflow Efficiency

The MRID 3D design enables quick setup, scanning and analysis of geometric distortion in as little as 10 minutes. The phantom is pre-filled with high T1W mineral oil and is self-contained with a controlled internal environment, which does not require maintenance over time. In addition, auto-detection and auto-registration processes support quick and accurate data analysis.

Geometric Accuracy and Stability

The MRID³ᴰ system is designed to maintain geometric integrity, resulting in accurate and reliable distortion analysis over the lifetime of the phantom. The combination of precisely machined fiducials, susceptibility-matched materials and structure volume stabilization features result in a superior geometric distortion solution.

Spherical Harmonic Analysis Detection Method

MRID³ᴰ uses a proven scientific method to quantify MR Geometric Distortion by adaptation of algorithms used in B0 shimming and gradient coil design. This innovative method allows for a highly accurate, hollow and lighter geometric distortion phantom. Combined with the phantom’s physical features, the MRID³ᴰ provides true submillimeter accuracy.

Automatic Phantom Registration

Accuracy is further improved by the incorporation of an XYZ detection feature, along with six contrastive fiducials at isocenter. MRID³ᴰ determines any discrepancy with DICOM coordinates and corrects the DVF to remove the effects of laser/couch misalignment or human error. This design promotes accurate data registration, even at high distortion levels.

Software

The QUASAR™ MRID³ᴰ software application is designed with specific needs of MR medical physicists and clinical workflow in mind. Accuracy, speed, and efficiency of results were primary considerations during the design process. The software application is optimized to run locally without load or latency issues, which results in less time waiting for cloud-based applications to generate 3D distortion vector fields. An unlimited scan license for one system is provided with QUASAR™ MRID³ᴰ. This allows users to test freely without the concern of depleting a defined quota of eligible scans. Additional system licenses are available upon request.

Efficient And Secure

Locally secure, client-based software designed for fast data transfer by using a built-in DICOM receiver. Advanced algorithms analyze 11,253 data points to report a high-resolution DVF. Results are typically available in under 10 minutes, including setup and scanning. Maintain control of your critical information without a need for cloud-based data management.

Real-time Visualization Tools

Interactive 3D DVF Viewer with ROI selector enables users to update displayed data in real-time to gain additional insights. Multiple visualization tools provide a variety of ways to easily interpret the analysis results. View and report data in statistical and graphical formats using a customizable, simple to use report generator.

QUASAR MRID³ᴰ advanced software provides users with the ability to monitor the performance of their MR system over time. By acquiring routine scans of the phantom on a consistent basis, users can detect changes in their MR system’s magnetic field which may contribute to system troubleshooting and preventative maintenance.

B0 And GNL Differentiation

QUASAR MRID³ᴰ provides the ability to report spherical harmonic coefficients and automatically quantify B0 and Gradient Non-Linearity distortions. Distortion characterization enables optimization of scan sequences for Radiation Therapy and increased inspection of the DVF. This feature is valuable in advanced imaging techniques such as Diffusion Weighted Imaging (DWI), which is greatly affected by GNL.

Unlimited Scan License

Unlike our competitors’ solutions, the MRID³ᴰ includes unlimited analyzed scans on one scanner with no expiry. This enables users to test freely without the concern of depleting a defined quota of eligible scans. An optional unlimited system scan license enables multi-system scanning over multiple sites with no expiry.

Accessories and Technical Specifications

Specifications

  • Phantom Material: Acrylic
  • Density: 1.18 g/cm³
  • Weight: 21 kg
  • Volume Susceptibility: χv= -9.01 x 10-6 @ 20°C
  • Contrast Media: 5 litres of high T1 contrast Paraffinic Mineral Oil
  • Contrast Volume Susceptibility: χv= -9.24 x 10-6 @ 20°C
  • Contrast Density: 0.83 g/cm³, T1= ~300ms @1.5T, Dielectric Constant εr <3
  • Physical Dimensions: 39.4 cm diameter by 39.1 cm long
  • Imaging Dimensions: 36.8 cm diameter by 32.1 cm long
  • Internal Volume: hollow, 33 cm diameter x 27 cm long, ~25 liters

Minimum Technical Requirements

  • Operating System: Windows 7 SP1 or higher
  • Processor: Intel Core™ i7 or better
  • Hard Disk Space: 10 GB minimum (64-bit)
  • RAM: 8 gigabyte (GB) or more
  • Screen Resolution: 1920 x 1080 pixels
  • Graphics Card: Intel HD Integrated Graphics or Nvidia GeForce GTX 750 or better

100-1018: MRID³ᴰ Geometric Distortion Analysis System, includes;

  • 1-Phantom
  • 1-Software License
  • User's Guide

500-5040: Additional Software License

  • 1-Software License

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT