Skip to content

Quality Assurance & Dosimetry

PhantomX Uniform Abdomen Phantom Low-contrast spheres

Including the liver, spleen and the spine, this phantom can be used in CT (including CBCT) to assess the detectability of spherical low-contrast lesions in a uniform liver background.

PhantomX Uniform Abdomen Phantom Low-contrast spheres

Including the liver, spleen and the spine, this phantom can be used in CT (including CBCT) to assess the detectability of spherical low-contrast lesions in a uniform liver background.

Compatible with: CT Simulation

Used for: Abdomen

Uniform Abdomen Phantom Low-contrast spheres

This phantom is a semianthropomorphic phantom representing the abdomen including the liver, spleen and the spine. Organ contours do not change throughout the entire phantom.

The phantom has 64 spherical lesions in the liver with 8 and 12 mm diameter and lesion contrasts of 10, 20, 30 and 40 HU to the surrounding liver.

The phantom can be used in CT (including CBCT) to assess the detectability of spherical low-contrast lesions in a uniform liver background.

Features

Specifications

  • Size: Approx. 259 x 190 x 150 mm
  • Weight: Approx. 5480 g
  • Base material: Cellulose-polymer composite
  • Optimal tube voltage: 120 kVp – adaptable upon request –

Diagnostic features

64 spherical liver lesions in 7 sections.

Lesion diameter: 8 mm and 12 mm Lesions contrasts: 10, 20, 30 and 40 HU at 120 kVp

Section 1: 8 lesions Section 2: 8 lesions Section 3: 8 lesions Section 4: 12 lesions Section 5: 12 lesions Section 6: 8 lesions Section 7: 8 lesionss.

Packaging & Dimensions

The product ships in a protective hard case featuring interior foam padding.

  • Dimensions (case): 415 x 280 x 190 mm
  • Dimensions (packaged)*: 465 x 355 x 210 mm
  • Total weight (ready to ship): 12.0 kg

*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT

Talk to our team

Questions about a system, a quotation or after-sales support? Call or email us and the right person will get back to you.