Skip to content

Quality Assurance & Dosimetry

PhantomX Abdomen Phantom Aortic aneurysm

Abdomen phantom for CT imaging evaluation, optimization, and training.

PhantomX Abdomen Phantom Aortic aneurysm

Abdomen phantom for CT imaging evaluation, optimization, and training.

Compatible with: CT Simulation

Used for: Abdomen

Abdomen Phantom Aortic aneurysm

This phantom simulates a contrast medium enhanced abdomen in arterial phase. It covers the first lumbar vertebra to the fourth sacral vertebra.

It has an infrarenal abdominal aortic aneurysm.

The phantom can be used in CT (including CBCT) to evaluate and optimize imaging performance and post-processing applications, including AI-enabled applications. It is also suited for training purposes.

The phantom provides a detailed and realistic simulation of soft and bone tissue. Air voids are filled with a cellulose-polymer composite of approx. -160 HU.

Features

Specifications

  • Size: Approx. 224 x 190 x 152 mm
  • Weight: Approx. 4400 g
  • Base material: Cellulose-polymer composite
  • Optimal tube voltage: 120 kVp – adaptable upon request –

Diagnostic features

Realistic simulation of vasculature, bone and soft tissues, including the liver, pancreas, spleen, adrenals, kidneys, stomach, small intestine and colon.

Liver cirrhosis, cholecystectomy, inferior vena cava filter, kidney cysts, kidney stone, lymph nodes.

Packaging & Dimensions

The product ships in a protective hard case featuring interior foam padding.

  • Dimensions (case): 415 x 280 x 190 mm
  • Dimensions (packaged)*: 465 x 355 x 210 mm
  • Total weight (ready to ship): 11.0 kg

*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT

Talk to our team

Questions about a system, a quotation or after-sales support? Call or email us and the right person will get back to you.