myQA SRS for CyberKnife®

Expand your myQA SRS workflow from Patient QA to Machine QA.

myQA SRS for CyberKnife®

Compatible with: Robotic linac, SRS / SBRT, Small Field Dosimetry, TG135

Used for: Beam Profile Analysis for CyberKnife®, Delivery and Plan Verification (RT), Monthly QA RT

NEW: CyberKnife Machine QA

Expand your myQA SRS workflow from Patient QA to Machine QA.

With the upcoming CyberKnife Machine QA package in myQA 2026-001, myQA SRS supports key daily and monthly QA procedures in a single filmless workflow. Replace time-consuming film-based measurements with automated, high-resolution digital QA and benefit from instant results, centralized data storage, and trend analysis.

Supported CyberKnife QA tests

  • Accelerator output Constancy
  • Auto QA (AQA)
  • Laser/radiation beam coincidence
  • Beam constancy (Iris, cone, MLC)
  • MLC Tests

Key benefits

  • Film-like resolution with digital efficiency
  • Instant results with automatic data acquisition
  • Time savings across routine QA procedures
  • No film handling or recurring film costs
  • One platform for both Patient QA and Machine QA

Digital Patient QA in Native Plan Geometry

myQA SRS for CyberKnife® provides all tools CyberKnife® users need for accurate and fast patient specific pretreatment QA and linac beam analysis.

With 0.4 mm film-class resolution and a 12 × 14 cm² sensor area, myQA SRS for CyberKnife ® combines the accuracy and resolution of Film QA with the proven efficiency of a digital detector array. Patient Specific QA workflow supports measurements and analysis in the native plan geometry to fully match patient treatment delivery.

  • CyberKnife ® specific fiducials support easy positioning of the myQA SRS System
  • Film-class digital resolution and efficiency
  • Automatic SAD and Angular correction
  • Seamless QA of millimetric target sizes with multiple measurement points
  • Evaluation of multiple targets at once
  • Fast digital detector array readout speed

Experience with myQA SRS for CyberKnife®

  • “With angular and SAD corrections applied, the myQA SRS array provided very good results and high agreement with the TPS data and is well-suited for pretreatment verification of CyberKnife ® SRS plans.” Dr. Kim Holm, Medical Physicist, Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT