Quality Assurance & Dosimetry

myQA Phoenix

Unrivaled accuracy, efficiency, and reliability for independent Proton Therapy system commissioning and acceptance.

myQA Phoenix

Unrivaled accuracy, efficiency, and reliability for independent Proton Therapy system commissioning and acceptance.

Compatible with: Carbon Compatible, Synchro-Cyclotron, Cyclotrons, Proton Therapy, TG224

Used for: Commissioning PT, Annual QA PT

myQA Phoenix transforms Proton Therapy

The new and unique design of myQA Phoenix resolves the clinical challenges and enables a reliable commissioning and acceptance of all proton therapy systems.

The system is more stable without the need for optical calibrations (geometry and intensity). The lightweight design allows for easier handling and makes the system less sensitive to transport.

As a result, new proton therapy centers can start clinical patient treatments significantly earlier and with the confidence of a highly accurate treatment planning and delivery process.

Key benefits for your PT commissioning and acceptance

Clear Accuracy

  • >4 million pixels with 0.2 mm resolution.
  • Distortion-free measurement accuracy.

Clear Efficiency

  • 1 minute fast setup and easy handling.
  • Save time with faster commissioning and sooner acceptance.

Clear Reliability

  • Instant confidence through reliable measurements and comprehensive analysis.
  • Easily perform regular checks anytime.

Benefits for high-resolution PT beam measurement accuracy

  • Amorphous silicon detector avoids measurement distortions that are inherent with optical systems.
  • Versatile single shot and movie mode measurements.
  • Optimized for PBS (pulsed or continuous).

myQA software

Optimized for PT installations, acceptance, and commissioning measurements and validation.

Easy and seamless handling

  • Compact design (582 × 522 × 31 mm³)
  • Minimal weight (13 kg)

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT