Quality Assurance & Dosimetry

myQA Patients

Advanced Patient QA on the global QA platform, from IMRT & VMAT to SRS / SBRT plan verification, used with

myQA Patients

Advanced Patient QA on the global QA platform, from IMRT & VMAT to SRS / SBRT plan verification, used with

Compatible with: Carbon Compatible, Robotic linac, C-arm linacs, Cyclotrons, Bore-type linacs, IMRT / VMAT, Proton Therapy, Helical linac, Small Field Dosimetry, SRS / SBRT, Synchro-Cyclotron, TG218, TG135, TG148

Used for: Delivery and Plan Verification (RT), Delivery and Plan Verification PT

Workflow efficiency

Fast preparation of new patient data and equipment

  • Enhance your clinical workflow
  • Fast and seamless data preparation
  • Office-based preparation
  • Flexible DICOM interface
  • Guided workflow navigation
  • Centralized data management

Workflow-guided menu

Streamline your workflow

  • Save time with fewer and optimized steps
  • Save your measurements in the central database
  • Analyze immediately or at your convenience

Discover myQA Patients highlights interactively

Film dosimetry

  • Highest resolution without angular dependence.
  • Ideal for SBRT and SRS validation & verification.
  • Single- and multichannel film dosimetry supported.

Automated one-click data alignment

Auto-alignment of your measured dataset with your reference. Speed up Patient QA workflow and provide consistent results during the measurement session:

  • Automated alignment as default, manual alignment supported if necessary.
  • Shifts are reported for the aligned dose maps along central axis.
  • Shifts from automatic or manual alignment can be applied to all the data in the measurements folder.

One-click isocenter location

  • myQA Patients automatically calculates the exact plan isocenter position based on the DICOM information.

Select isocenter plane

  • Select the plane of choice manually and mark it as the isocenter plane (alternative to the automated process).

Isocenter plane definition and plane distance calculation

  • The isocenter plane is automatically highlighted, including the plane position.
  • Display of the distance between each dose planes according to the plan calculation grid size.

TG-218 reference dose gamma calculation

For gamma analysis, TG-218 advises to use the global normalization with reference dose selection as the better approach, compared to the maximum dose.

  • myQA Patients provides reference dose gamma calculation formalism.
  • For gamma analysis, select the 90% from the maximum dose, or any other value in Gy or %.

Comprehensive and efficient analysis of planned vs. measured treatments

  • Wide range of algorithms for data processing
  • 1D and 2D visual and mathematical analysis tools
  • Relative and absolute gamma evaluation
  • Rapid calculation and quick review of results in the software as well as on myQA Cockpit

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT