Advanced Patient QA on the global QA platform, from IMRT & VMAT to SRS / SBRT plan verification, used with
Compatible with: Carbon Compatible, Robotic linac, C-arm linacs, Cyclotrons, Bore-type linacs, IMRT / VMAT, Proton Therapy, Helical linac, Small Field Dosimetry, SRS / SBRT, Synchro-Cyclotron, TG218, TG135, TG148
Used for: Delivery and Plan Verification (RT), Delivery and Plan Verification PT
Workflow efficiency
Fast preparation of new patient data and equipment
- Enhance your clinical workflow
- Fast and seamless data preparation
- Office-based preparation
- Flexible DICOM interface
- Guided workflow navigation
- Centralized data management
Workflow-guided menu
Streamline your workflow
- Save time with fewer and optimized steps
- Save your measurements in the central database
- Analyze immediately or at your convenience
Discover myQA Patients highlights interactively
Film dosimetry
- Highest resolution without angular dependence.
- Ideal for SBRT and SRS validation & verification.
- Single- and multichannel film dosimetry supported.
Automated one-click data alignment
Auto-alignment of your measured dataset with your reference. Speed up Patient QA workflow and provide consistent results during the measurement session:
- Automated alignment as default, manual alignment supported if necessary.
- Shifts are reported for the aligned dose maps along central axis.
- Shifts from automatic or manual alignment can be applied to all the data in the measurements folder.
One-click isocenter location
- myQA Patients automatically calculates the exact plan isocenter position based on the DICOM information.
Select isocenter plane
- Select the plane of choice manually and mark it as the isocenter plane (alternative to the automated process).
Isocenter plane definition and plane distance calculation
- The isocenter plane is automatically highlighted, including the plane position.
- Display of the distance between each dose planes according to the plan calculation grid size.
TG-218 reference dose gamma calculation
For gamma analysis, TG-218 advises to use the global normalization with reference dose selection as the better approach, compared to the maximum dose.
- myQA Patients provides reference dose gamma calculation formalism.
- For gamma analysis, select the 90% from the maximum dose, or any other value in Gy or %.
Comprehensive and efficient analysis of planned vs. measured treatments
- Wide range of algorithms for data processing
- 1D and 2D visual and mathematical analysis tools
- Relative and absolute gamma evaluation
- Rapid calculation and quick review of results in the software as well as on myQA Cockpit