Skip to content

Quality Assurance & Dosimetry

myQA iON for Particle Therapy

myQA iON is the unique Patient Quality Assurance (PQA) software solution for efficiency, accuracy, and safety of recurrent QA checks in Particle Therapy.

myQA iON for Particle Therapy

myQA iON is the unique Patient Quality Assurance (PQA) software solution for efficiency, accuracy, and safety of recurrent QA checks in Particle Therapy.

Compatible with: Synchro-Cyclotron, Cyclotrons, Proton Therapy, Heavy Ions

Used for: Delivery and Plan Verification PT

End-to-end Accuracy

  • High accuracy through leading-edge Monte Carlo dose computation.
  • Verify TPS plan dose vs. Independent Monte Carlo dose.
  • Verify TPS plan dose vs. Log-reconstructed dose.

End-to-end Efficiency

  • Save significant time through Patient QA workflow and process automation.
  • Overcome time consuming detector measurements at isocenter.
  • Monte Carlo and machine logs QA calculations in the background.

End-to-end Confidence

  • Verify treatment delivery quality of each fraction, until the last fraction.
  • No additional QA workload required through automatic log transfer and analysis.
  • Automatic fractional dose reconstruction based on treatment delivery/machine logs.

Centralized workflow management

Take control of your Patient QA workflow with centralized Queue Management. Get real-time visibility of queued and running tasks, prioritize tasks according to your workflow needs, and efficiently manage user actions.

  • Centralized QA workflow processing
  • Real-time visibility of queued and running tasks
  • Flexible task prioritization and controlled user actions
  • Faster navigation between pages and tabs
  • Improved PT log file import reliability
  • Enhanced stability during server interruptions

Independent Monte Carlo

  • Verify TPS dose vs. independent Monte Carlo dose via 3D gamma algorithm
  • One click workflow: simply send the TPS DICOM data to myQA iON
  • Automatic Monte Carlo calculation in the background
  • High accuracy with sophisticated Monte Carlo dose map computation
  • Easy integration in your routine QA workflow

3D Monte Carlo Analysis

  • Fully automated independent Monte Carlo dose computation.
  • Verify TPS dose vs. independent Monte Carlo dose.
  • 3D gamma analysis and difference dose map.
  • Display and verify independent Monte Carlo and log reconstructed dose vs. TPS plan dose on patient anatomy (and DVH verification).
  • Define and compare clinical goals with the ones from the TPS.

3D Log Analysis

  • 3D Monte Carlo dose reconstruction based on the actual treatment delivery logs.
  • Verify each treatment fraction, not just pretreatment (dry run).
  • Track the fractions-accumulative delivered dose.
  • Intuitive visualization of TPS planned vs. actual delivered spot map, and analysis of spot position error for each energy layer.

QA time saving through logs and automation

  • myQA iON uniquely integrates machine log QA, allowing up to 5 times faster Patient QA. 1
  • Eliminate time consuming detector measurements at isocenter.
  • Fully automated TPS DICOM and machine log data processing, and automated trigger of all calculations in the background.
  • User-defined log analysis, result display & verification with customized thresholds for warning and error management.
  • Process automation saves you from tedious and error-prone manual QA operations and status checks.
  • Automatic data retrieval and background processing.
  • Easy integration in your routine QA workflow.
  • Monitor your complete QA status in one comprehensive overview.
  • Minimize your setup times through automatic grouping of identical tasks.
  • Easy management of all your QA tasks, due dates, and staff assignments.
  • Convenient network access: The web-client enables QA reviews on any device connected to your hospital network.

1 A Patient QA survey among 39 experienced medical physicists at Proton Therapy centers determined an average 80% time saving with myQA iON compared to traditional measurement-based Patient QA. The expected time saving at an individual site may vary depending on the application mix of log-file QA vs. measurements, the patient case distribution, and QA protocols.

  • myQA iON significantly reduces the time needed to complete Patient QA: Task-based workflow, automation, and the latest web-based software technologies increase QA efficiency while ensuring patient treatment safety.
  • myQA iON uniquely integrates 3 advanced Patient QA verification tools into 1 environment – enabling fast, accurate, and optimal treatment delivery – based on each individual case.
  • myQA iON delivers treatment safety fraction by fraction, including the last fraction, which can now be verified for the first time by utilizing the fractional treatment delivery logs.

In this division

DOSE-X

Next-Generation Reference Class Electrometer DOSE-X is a portable reference class electrometer exceeding IEC 60731 standards. Discover your perfect solution for conducting reference measurements according to DIN 6800, AAPM TG51, and IAEA TRS398. Compatible with Machine/Modality/Application: Carbon Compatible , C-arm linacs , Robotic linac , Cyclotrons , Bore-type linacs , IMRT / VMAT , Proton Therapy , Helical linac , Small Field Dosimetry , Synchro-Cyclotron , Ultra-high Dose Rate (UHDR) , TG106, TG142, TG148, TG224, TG51 Used for Workflow Commissioning PT, Commissioning and Annual QA RT, Annual QA PT, Monthly QA RT, Monthly QA PT

Talk to our team

Questions about a system, a quotation or after-sales support? Call or email us and the right person will get back to you.